The OPTIFLUX 6000 is an electromagnetic flowmeter (EMF) for hygienic applications in the food sector. The 3A and EHEDG certified flowmeter has industry-specific insertion lengths to meet the stringent requirements of the food and beverage industry.
general technical data | |
---|---|
Measuring principle | Magnetic-inductive |
Nominal widths | DN 2.5 to DN 150 |
Accuracy | Up to 0.3 % of the measured value |
Medium temperature | Up to 140 °C |
Process connection | DIN 11851, Tri-Clamp |
Lining | PFA |
Ambient temperature | Up to 65 °C |
Protection type | IP66/IP67, IP69 for stainless steel case |
Outputs | Analog output (4 to 20 mA) with HART and pulse/frequency/status |
Display | LCD display, white backlight for displaying up to 3 measured values |
Special features | EHEDG and 3A approval; optional stainless steel case |
3.51 MB, English
5/12/2022
4.4 MB, English
5/12/2022
2.62 MB, English
5/12/2022