The level probe measures the level of liquids continuously and hydrostatically. In ventilated tanks, filling heights from 1 to 100 mH2O can be achieved. The level probe is used, among other places, in ballast water tanks, pumping stations, and splash water containers.
general technical data | |
---|---|
Measuring range | 100 mbar to 10 bar (1 to 100 mH2O) |
Medium temperature | 0 to 50 °C |
Accuracy (linearity) | ±0.3 % |
Output signal | 4 to 20 mA, two-wire |
Housing material | Titanium or stainless steel |
Cable material | FEP, PUR |
Additional equipment | Reverse-polarity protection |
Protection type | IP68 |
Approval | ATEX; IECEx; EAC Ex [Ex i]; DNV; EAC |
Declaration of manufacturer | CE |
Application areas | Indoor installation, wastewater, well water, heating oil, car washes, diesel, seawater, caustic soda (20 %, 20 °C), rainwater, swimming pool (disinfectant: chlorine) |